Draeger accuro pump pdf

The dragertube pump accuro allows you to use the established dragertubes. Insert unopened drager detector tube into bellows pump. Draeger accuro colorimetric manual tube pump president and owner of pk safety, rick pedley shows you the trusted and reliable. Gas detector pump for all drager short term tubes and sampling tubes.

When the endofstroke indicator f1 appears, squeeze pump completely again. Preuse test draeger how to use the drager accuro gas detection pump 6400000 find how to use the drager accuro pump, suitable for use with hundreds of gas detection tubes. Cross instrumentation draeger accuro pump and how to. A builtin stroke counter tells you exactly how many strokes have been taken. The sampling process is completed when the body of the pump has opened completely. Second is the draeger accuro pump, which draws a calibrated, repeatable 100 ml sample of air through the tube using the manual internal bellows pump. The bellows design provides precise volume with very low maintenance. The display is backlit to enable use of the pump under poor lighting conditions. Draegertubes andaccuro pump environmental equipment. Ease of operation and a high degree of reliability compliment the measurement and sampling of gases, vapors and aerosols. Leak testing the drager accuro bellows pump technical note. All books are in clear copy here, and all files are secure so dont worry about it. When you deploy the draeger tube system, for portable gas detection, your draeger accuro pump must be in spec and working correctly.

The accuro manual gas detector pump is used for spot measurements with drager tubes. Beurtschipperstraat 1 3194 dk hoogvliet dock number. In addition to the manual bellowsstyle pump you get a spare parts kit, tube opener, rubber caps, an allen wrench, and a. Some of their products include the draeger parat 5530 fire escape hood, draeger accuro bellows pump and draeger gas detection tubes. The pharmaceutical industry requires significant gas monitoring on the production floor, in research and development laboratories, and in plant utility rooms, especially because of its use of inert or toxic chemicals in often confined spaces. For use with shortterm detector tubes see 453238 series. For your own safety, one hand must always remain free. The printed scale allows technicians to easily view the direct reading of the concentration. The pump is as critical to accurate measurement as the draeger tube.

Xact 5000 automatic tube pump the automatic tube pump draeger xact 5000 is the first allinone solution designed for measurements with draeger shortterm tubes and for sampling tubes and systems. The dragertube pump accuro allows you to use the established dragertubes to take measurements under extreme. Drager accuro gas detector pump ih sampling notes form drager detector tube procedure 1. Cross instrumentation draeger accuro pump and how to operate dan hines.

President and owner of pk safety, rick pedley shows you the trusted and reliable draeger accuro colorimetric manual tube pump. It draws a calibrated 100 ml sample of air through the drager tube with each stroke. Hold pump so that the endofstroke indicator and the stroke counter are facing the user f. The body of the pump consists of a bellows, which is completely pushed together for the measurement. To do this, seal the pump with an unopened drager tube and completely compress the bellows. Hardside kit ergonomic design allows easy measurement of more than 350 gasesincluding formaldehyde.

The draeger accuro manual pump hard case kit gives you everything you need to use draegers famous detector tubes to read levels of harmful gases. Dragertubes with the accuro pump deliver the most accurate results. Remember that the draeger accuro pump draws a calibrated, repeatable 100 ml sample of air through the tube using the manual internal bellows pump. Draeger soft side hand pump kit, includes accuro hand pump. Draeger safety d dsi training 2002 july 11, 2008 page 6 draeger tubes.

Pump is adequately leakproof if the endofstroke indicator has not appeared i. The pump is sufficiently airtight if the bellows has not expanded completely after 15 minutes. Draegertubes are glass vials filled with a chemical reagent that reacts to a specific chemical or family of. Detecting oxygen depletion is particularly important due to the use of nitrogen in. Draeger tubes are glass vials, filled with a chemical reagent that reacts to a specific chemical or family of chemicals. The drager accuro is a bellows pump, with which the air sample is drawn through the drager. The draeger accuro manual tube pump is a bellowsstyle hand pump used for making quick spot measurements and process checks for gas using draeger colormetric detector tubes in a wide variety of industrial workplaces. Quality assurance is accomplished by individually calibrating each. Find how to use the drager accuro pump, suitable for use with hundreds of gas detection tubes. Each stroke pulls 100 milliliters of sample air through a detector. Draeger accuro colorimetric manual tube pump youtube. Draeger hardside accuro pump kit gas detection warehouse.

The pump is compatible with over 500 different shortterm gas detection tubes and is suitable for many different applications. Gas detector pump for all drager short term tubes and. The exhaust valve is closed during the opening phase of the bellows so that the gas sample. The drager accuro is a bellows pump, with which the air sample is drawn through the drager tube using strokes. How to use the drager accuro gas detection pump youtube. A calibrated 100ml sample of air is drawn through the. When measuring, the pump body bellows is pressed together completely. The drager accuro pump can be an easy and costeffective method of gas detection. Draeger accuro pump, includes pump, manual, hex wrench and. Looking for draeger soft side hand pump kit, includes accuro hand pump, deluxe tube opener, spare parts kit, 10 rubber 3wzf2. This video demonstrates proper operation of this manual hand pump. The drager accuro gas detector pump allows you to use tried and tested drager tubes to take measurements under extreme conditions. Leak test procedure for the drager accuro bellows pump. Leading detection ever since 1937 when we introduced.

View the full range of draeger gas detection tubes here. How to use the drager accuro pump frontline safety blog. The pump is compatible with over 500 different shortterm. The drager accuro gas detection pump is ideal for onthespot measurements and works with a huge range of shortterm detection tubes. When the bellows is released, the air is drawn automatically and the gas sample to be measured is sucked through the tube being used.

Interchanging brands of pumps and tubes may produce a significant reduction in accuracy and is not recommended. Leak testing the drager accuro bellows pump technical. Stocking draeger tubes, draeger accuro tube pumps, soft side hard side. If the targeted chemicals is present the reagent in the tube changes color and the length of the color change typically indicates the measured concentration. Drager tubes with the accuro pump deliver the most accurate results. Draeger tubes used in todays workplace provide quantitative results with a high degree of accuracy, repeatability and selectivity. The onehanded operation is simple and allows you to reach places that a piston pump cannot go. How to use the drager accuro gas detection pump 6400000. The dragertube pump accuro draws in 100 ml per stroke. With the ability to be used singlehandedly, the drager accuro gas detector pump works to take gas measurements in extreme conditions.